OpenLock Derivitives by Start2 3d model
Warning. This content is not moderated and could be offensive.
m4
3dmdb logo
Thingiverse
OpenLock Derivitives  by Start2

OpenLock Derivitives by Start2

by Thingiverse
Last crawled date: 3 years ago
01/23/17 Updated Bases with OpenLock Standard Keyholes 6mm Plain Bases for your pattern design. Added XI Full size, XIA half size of a full XI, and added a reason for XIA, a buttressed wall. Also added XI Theory (slots on both sides, probably redundant/superfluous) Thanks for looking.
Projecting a further discussion on OpenLock tile options. Currently the standard options on curves are the F, with G and H walls/half floors and the V, with X walls/half floors. A W fills out the V to a 4x4 square.
Moved discussion from: http://www.thingiverse.com/thing:2038362
Kudos to:http://www.printablescenery.com/product-category/rampage-system/
Extrapolating Tile options S=1" wide, E=2" wide
FI= A curved I (1") with end Openlock connections and Openlock connection on the curve side. Combining 4 walls would make a 2"dia column. As it is a curved, small radius, 1" size matching width to the I series, combining the F and I to create an FI.
FE= Centerline F outside radius. A curved 2" wide tile with end Openlock connections and Openlock connections on curve sides. As it is a curved, small radius, 2" size matching width to the E series, combining the F and E to create an FE.
VE= Centerline V outside radius. A curved 2" wide tile with end Openlock connections and Openlock connections on curve sides. As it is a curved, large radius, 2" size matching width to the E series, combining the V and E to create an VE.
FS= A piece between the H/HS and FI curved tiles with end Openlock connections and Openlock connections on both sides. As is matches an F on the OUTSIDE radius and matching width to the S series, calling it an FS.
HS= An H with end Openlock connections and Openlock connections on both sides. Called an H and matching to the S series to create an HS.
VS= (Previous VS discussion was called X-)A piece between the H/HS and X curved tiles with end Openlock connections and Openlock connections on both sides. As is matches an V on the OUTSIDE radius and matching width to the S series, calling it an VS.
HE= Centerline H outside radius. A curved 2" wide tile with end Openlock connections and Openlock connections on curve sides. As it is a curved, large radius, 2" size matching width to the E series, combining the H and E to create an HE.
XI= A 1" wide X inside radius. Don't know if needed, but included as a possible need.
Also options for different spacing for round hallways on some tiles other than the 4x4 that the standard tiles are based. This will open up for uses in curved roadways, mine track curves and tower options.
Tiles are 6MM 25.4 based.

Tags