GrabCAD
Synergetic reducer of the tremor amplitude
by GrabCAD
Last crawled date: 1 year, 11 months ago
Known DRIFTS Project Report [1] (Dynamically Responsive Intervention For Tremor Suppression) offers several ways to reduce tremor by external mechanical devices:
- Orthosis Support Structure providing force effect on skin pressure receptors;
- Absorption of tremor vibration energy through dissipation:
- Decrease in the amplitude of oscillations by increasing the weight:
- Elastic resistance to deviation of the wrist from the physiologically neutral position.
In this application, the author tried to combine all of these devices in one
Device comprises a several chambers made of flexible airtight fabric. For example, there are three cameras in real device there may be more. In each chamber using a funnel can be covered with a certain amount of filler. The chamber can be left blank. Fillers: polystyrene granules, sand, metal powder or granules or mixtures thereof.
The result: an increase in weight, the dissipation of tremor energy by filling.
The each chamber may be evacuated by the air pump, a vacuum cleaner or syringe. Chambers hell impacts hand creating pressure and support structure.
By pressing on the valve sideways air enters the chamber and the shell straightened.
By varying the amount of filler and the vacuum device precise adjustment of the patient's hand. Extras Velcro fastener can be used Velcro fastener.
For more details see pdf file text_tremor
- Orthosis Support Structure providing force effect on skin pressure receptors;
- Absorption of tremor vibration energy through dissipation:
- Decrease in the amplitude of oscillations by increasing the weight:
- Elastic resistance to deviation of the wrist from the physiologically neutral position.
In this application, the author tried to combine all of these devices in one
Device comprises a several chambers made of flexible airtight fabric. For example, there are three cameras in real device there may be more. In each chamber using a funnel can be covered with a certain amount of filler. The chamber can be left blank. Fillers: polystyrene granules, sand, metal powder or granules or mixtures thereof.
The result: an increase in weight, the dissipation of tremor energy by filling.
The each chamber may be evacuated by the air pump, a vacuum cleaner or syringe. Chambers hell impacts hand creating pressure and support structure.
By pressing on the valve sideways air enters the chamber and the shell straightened.
By varying the amount of filler and the vacuum device precise adjustment of the patient's hand. Extras Velcro fastener can be used Velcro fastener.
For more details see pdf file text_tremor
Similar models
grabcad
free
Synergy
...onnection.
3. you can give up the air switch and permanently connected hose. instead of setting one or two valves for each pillow
grabcad
free
air compressor
...mpressed air). by one of several methods, an air compressor forces more and more air into a storage tank, increasing the pressure
grabcad
free
Vacuum vessel
...um environment allows researchers to conduct physical experiments or to test mechanical devices which must operate in outer space
grabcad
free
Hand tremor controller
...ded certain pressure and makes the fingers to hold tight there by reducing the tremors and this is mostly useful for old persons.
grabcad
free
Wrist support brace
...and and damping of tremors. speed of motion can be reduced using this solution.
please feel free to critique and share opinions.
grabcad
free
Energy Recovering Device
...tant production of fresh water. the energy recovery device does not require any auxiliary energy and is a pure mechanical device.
grabcad
free
Air Compressor
... diesel engine or a gasoline engine) into potential energy by forcing air into a smaller volume and thus increasing its pressure.
grabcad
free
Turbo Impeller
...and proportionately more fuel—into the combustion chamber than atmospheric pressure (and for that matter, ram air intakes) alone.
grabcad
free
Turbo charger
...re air and thus proportionately more fuel into the engine’s combustion chamber than the intake at the atmospheric pressure alone.
grabcad
free
Jet Engine
... the model can then be refined with additional details and features such as air inlets, cooling systems, and structural supports.
Tremor
grabcad
free
Hand tremor
...hand tremor
grabcad
tremor stabilizing bracelet
grabcad
free
Hand tremor controller
...ded certain pressure and makes the fingers to hold tight there by reducing the tremors and this is mostly useful for old persons.
grabcad
free
Tremor Canceling Braclet
...atient would notice them less often and would be able to deal with them easily. it could also be scaled down to a ring sized one.
grabcad
free
Tremor Canceling Ring
...lly induced tremors could be reduced because the patient would notice them less often and would be able to deal with them easily.
grabcad
free
Tremor Brace
... to the patient's anatomy. replacing the one-piece design with a ball joint would potentially allow for more wrist movement.
grabcad
free
VA-Tremor Stabilizer
... : i use the image in the link below (from google) :
www.3dscience.com/img/products/3d_models/medical/medical-glove-wireframe.jpg
grabcad
free
MECHANICAL HAND TREMOR STABILIZER
...itself.
springs used in this gadget needs to be calibrated well , to eliminate required amplitudes and frequencies of vibration.
grabcad
free
VA Challenge, Tremor damping system
...m others, and please send me any considerations you may have. it has been an exciting and rewarding challenge to design thus far.
grabcad
free
Stabilizer Hand Tremors
...i1gnee
http://www.stockwell.com/data-sheets/bf2000.pdf
http://www.stockwell.com/data-sheets/poron-4790-92-extra-soft-slow-reb.pdf
Amplitude
grabcad
free
Oscillator amplitude
...oscillator amplitude
grabcad
oscillator amplitude max 125mm driven by toothed belt schneider_electric cas41brm0125a
grabcad
free
Oscillator amplitude max 12mm driven by toothed belt
...ax 12mm driven by toothed belt
grabcad
oscillator amplitude max 12mm driven by toothed belt schneider_electric car43bcm0012a1nr1
grabcad
free
Parametric Star
...parameters (select tools>parameters and set custom value) set relation: dimension=75+sin(trajpar*360*number_of_arms)*amplitude ...
grabcad
free
Oscillator driven by toothed belt
...oscillator driven by toothed belt grabcad oscillator amplitude max 40mm driven by toothed belt schneider_electric...
grabcad
free
Inductive Proximity Switch
...this causes a load on the sensor, decreasing the amplitude of the electromagnetic field. as the target approaches the...
grabcad
free
Actuators for Stewart
...stewart system, which would be useful for improving the amplitude characteristics of the adaptive...
grabcad
free
Badminton Basket
...of badminton basket. you can change the number_of_arms and amplitude parameters (select tools>parameters and set custom...
grabcad
free
Biomimetic Marine Propeller
...naca 63(4)-021 45 degrees blade twist tubercles have 2.5% amplitude of chord...
grabcad
free
Biomimetic Marine Propeller
...naca 63(4)-021 45 degrees blade twist tubercles have 5% amplitude of chord...
Reducer
grabcad
free
Reducer
...reducer
grabcad
reducer
grabcad
free
reducer
...reducer
grabcad
reducer
grabcad
free
Reducer
...reducer
grabcad
reducer
grabcad
free
reducer
...reducer
grabcad
reducer
grabcad
free
reducer
...reducer
grabcad
reducer
grabcad
free
reducer
...reducer
grabcad
reducer
grabcad
free
Reducer
...reducer
grabcad
reducer
grabcad
free
reducer
...reducer
grabcad
reducer
grabcad
free
Reducer
...reducer
grabcad
reducer
grabcad
free
Reducer
...reducer
grabcad
reducer