Familiy house - obiteljska kuća 3d model
3dmdb logo
GrabCAD
Familiy house - obiteljska kuća

Familiy house - obiteljska kuća

by GrabCAD
Last crawled date: 1 year, 11 months ago
Objekat se sastoji od podruma, prizemlja i kata. Vanjski zidovi podruma rađeni su od armiranog betona sa potrebnom hidroizolacijom i termoizolacijom, a unutarnji nosivi i pregradni zidovi rađeni su od blok-opeke. Ispod AB ploče podruma nasut je šljunak u sloju od 40cm(radi kapilarnog dizanja vode) koji je nakon nasipanja nabijen u jednom sloju. AB podna ploča podruma također je izolirana sa potrebnom hidroizolacijom i termoizolacijom. Zidovi prizemlja i kata rađeni su od blok-opeke sa potrebnom izolacijom. Svi pregradni zidovi rađeni su od opeke debljine 10cm. Međukatne konstrukcije rađene su od armiranog betona sa potrebnom izolacijom i oblogom. Konstrukcija krova rađena je isključivo od drvene građe a pokrivena je crijepom „Tondach mediteran“. Na objekat su ugrađeni PVC otvori(prozori i vanjska vrata), a sva unutarnja vrata su od drveta. Ograda na balkonima objekta je od inoxa. Vertikalne komunikacije, odnosno stubište, rađeno je od armiranog betona, a gazište i čelo stepenica obločeno je kamenim pločama. Fasada objekta rađena je po sistemu „Demit fasada“ koji je bio optimalno rješenje za ovaj objekat. Svi AB dijelovi objekta rađeni su betonom C25/30, koji je dovoljno čvrst za sva naprezanja koja se javljaju ili bi se mogla javiti. Termoizolacija objekta je određena tako da objekat ima što manju potrošnju energije i bude ugodan za boravak pri različitim temperaturama.

Eng.
The building consists of a basement, ground and first floors. Exterior basement walls were made of reinforced concrete with the required waterproofing and thermal insulation, and interior bearing and partition walls were made of brick block. Under AB basement slabs poured gravel in a layer of 40cm (due to capillary rising water), which after filling packed in a single layer. AB basement floor slab has also been isolated with the necessary waterproofing and thermal insulation. The walls of the ground and first floors were made of brick block with the necessary insulation. All walls were made of bricks 10 cm thick. The ceiling joists were made of reinforced concrete with the required insulation and cladding. Roof construction was done exclusively by timber and covered with tiles "School Photos Mediterranean." At the facility are built PVC openings (windows and exterior doors), and all interior doors are made of wood. Railing on the balcony of the building is made ​​of stainless steel. Vertical communication or staircase, made of reinforced concrete, and the tread and forehead stairs coated with stone slabs. Facade of the building was done according to the "Dryvit" which was the optimal solution for this item. All AB parts of the building were made with concrete C25 / 30, which is tough enough for all the stresses that occur or could occur. The insulation of the building is determined so that the facility has less power consumption and is pleasant to stay at various temperatures.

Tags